COMPANY HEADER
Request Information
  • Hermetically Sealed
  • Case Isolated
  • TEDS Feature
Unit of Measure

Specifications

Brands

N/A Dytran

Physical

Maximum Weight (Less Cable)

N/A 1.8 oz52 g

Connector Type

N/A 4-Pin

Note for Connector Type

N/A Mates with Glenair connector 800-006-16-Z16-4SN. Dytran cable model 6380AXX

Thru Hole Mounting Provision

N/A Ø.195 Inch Ø4.95 mm

Sensing Element Material

N/A Quartz

Sensing Element Mode

N/A Shear

Material

N/A 300 Series S.S.

Environmental

Maximum Peak Vibration (±)

N/A 1200 g11772 m/s²

Operating Temperature Range

N/A -67 to +302 ºF-55 to +150 ºC

Environmental Seal

N/A Hermetic

Maximum Peak Shock (±)

N/A 2000 g19620 m/s²

Transducer Electronic Data Sheet (TEDS) Operating Temperature

N/A -40 to +185 ºF-40 to +85 ºC

Base Strain Sensitivity

N/A 0.003 g/µε0.03 m/s²/µε

Performance

Resonant Frequency

N/A >30 kHz

Full Scale (F.S.) Linearity (±)

N/A ±1 %

Note for Full Scale (F.S.) Linearity (±)

N/A Measure using zero-based straight line method, % of F.S. or any lesser range

Maximum Transverse Sensitivity

N/A <6 %

Peak Acceleration Range (±)

N/A 1000 g9810 m/s²

Frequency Response at ±3 Decibel (dB) Bandwidth

N/A 0.3 to 6000 Hz

Maximum Root-Mean-Square (RMS) Noise Floor

N/A 0.02 g0.2 m/s²

Frequency Range ±10%

N/A 0.6 to 4000 Hz

Frequency Response ±5%

N/A 1 to 3000 Hz

Sensitivity ±20%

N/A 5 mV/G0.51 mV/m/s²

Note for Sensitivity ±20%

N/A Measured at 100Hz, 1Grms per ISA RP 37.2

Electrical

Discharge Time Constant

N/A 0.5 to 2.0 sec

Typical Output Impedance

N/A 100 O

Direct Current (DC) Bias Voltage

N/A 7.0 TO 12 V

Direct Current (DC) Compliance Voltage Range

N/A +18 to +30 V

Ground Isolation

N/A >1 GO

Power Supply Current Range

N/A 2 to 20 mA

Note for Power Supply Current Range

N/A Do not apply power to this system without current limiting, 20mA MAX, To do so will destroy the IC charge amplifier

TEDS Feature

N/A IEEE 1451.4