COMPANY HEADER
Request Information
  • Ground Isolated
  • Hermetically Sealed
  • Stud Mount
  • TEDS Capability
  • IP68 Rated, Fully Submersible
Unit of Measure

Specifications

Brands

N/A Dytran

Electrical Isolation

N/A >100 MO

Physical

Housing Material

N/A Titanium

Sensing Element

N/A Shear

Maximum Weight (Less Cable)

N/A 0.6 oz18 g

Mounting Provision

N/A 10-32 Stud Mount

Integral Cable Type

N/A 4x 28AWG, Water-blocked

Housing Isolation

N/A Case Isolated

Sensing Element Material

N/A Single Crystal

Note for Integral Cable

N/A Model number: 3623AXT-XX. "XX" denotes cable length in feet.

Environmental

Maximum Peak Vibration (±)

N/A 600 g5886 m/s²

Operating Temperature Range

N/A -67 to +212 ºF-55 to +100 ºC

Environmental Seal

N/A Hermetic

Maximum Peak Shock (±)

N/A 1000 g9810 m/s²

Transducer Electronic Data Sheet (TEDS) Operating Temperature

N/A -40 to +185 ºF-40 to +85 ºC

Base Strain Sensitivity

N/A 0.002 g/µε0.02 m/s²/µε

Performance

Note for Sensitivity

N/A Measured at 100 Hz, 1 Grms per ISA RP 37.2.

Resonant Frequency

N/A >15 kHz

Full Scale (F.S.) Linearity (±)

N/A 1 %

Note for Full Scale (F.S.) Linearity (±)

N/A Measured using zero-based best straight-line method.

Maximum Transverse Sensitivity

N/A 6 %

Peak Acceleration Range (±)

N/A 500 g4905 m/s²

Root-Mean-Square (RMS) Noise Floor

N/A 0.007 g0.07 m/s²

Sensitivity ±5%

N/A 10 mV/g1.02 mV/m/s²

Frequency Range ±10%

N/A 0.9 to 4000 Hz

Frequency Response ±5%

N/A 1.4 to 3000 Hz

Note for Sensitivity ±5%

N/A Measured At 100 Hz, 1 Grms per ISA RP 37.2.

Frequency Range ±5%

N/A 1.4 to 3000

Electrical

Discharge Time Constant

N/A 0.4 to 1.5 sec

Transducer Electronic Data Sheet (TEDS) Feature

N/A IEEE 1451.4

Typical Output Impedance

N/A 100 O

Note for Transducer Electronic Data Sheet (TEDS) Feature

N/A TEDS is unlocked version.

Direct Current (DC) Compliance Voltage Range

N/A +18 to +30 V

Power Supply Current Range

N/A 2 to 20 mA

Maximum Ambient Pressure

N/A 100 psi0.69 MPa

Note for Power Supply Current Range

N/A Do not apply power to this device without current limiting, 20mA Max, to do so will destroy the integral IC amplifier.

TEDS Feature

N/A IEEE 1451.4

Direct current (DC) Output Bias Voltage

N/A 7.0 to 12.0 V

Supplied Accessories

Supplied Accessories

N/A
  1. Accredited calibration certificate (ISO 17025).
  2. Mounting stud model 6200, (10-32 to 10-32), qty 1.