COMPANY HEADER
Request Information
Designed expressly for Health and Usage Monitoring Systems (HUMS), the Dytran model 3079A is an IEPE piezoelectric accelerometer, featuring a sensitivity of 10 mV/g with a frequency response of 1.5 to 5,000 Hz in a highly rugged stainless steel package weighing 11 grams.

The distinguishing feature of model 3079A is the Dytran developed integral mounting bracket design, facilitating improved sensor performance while eliminating costs associated with separate mounting brackets. The miniature accelerometer is mounted within the bracket at the point where the cable and bracket are joined. This unique design also offers a reduced mass, as compared to conventional sensors and mounting brackets. Model 3079A is hermetically sealed for reliable operation within high-humidity and dirty environments as well as case isolated, to avoid ground loop interference.
Unit of Measure

Specifications

Brands

N/A Dytran

Accelerometer Type

N/A Airborne

Measuring Acceleration Range

N/A 500 g4903 m/s²

Frequency Response

N/A 1.5 to 5,000 Hz

Frequency Response Gain

N/A -10 dB+10 dB

Spectral Noise

N/A B

Electrical Isolation

N/A 1

Maximum Shock

N/A 3000 g29420 m/s²

Recommended Cabling Accessories

N/A Integral 14-foot cable assembly (supplied)

Physical

Housing Material

N/A Stainless Steel

Sensing Element

N/A Quartz, Shear

Weight

N/A 11 g0.39 oz

Environmental

Temperature Range

N/A -60 to 250 ºF-51 to 121 ºC

Thermal Coefficient of Sensitivity

N/A 0.03 %/°F0.06 %/°C

Environmental Seal

N/A Hermetic

Performance

Sensitivity

N/A 10 mV/g1 mV/m/s²

Quality Management System

Quality Management System

N/A Dytran Instruments Quality Management System meets the requirements of the following standards:
  • ISO 9001:2008 and AS 9100 Revision C and in accordance with requirements of AS9104A
  • ISO/IEC 17025:2005 and ANSI/NCSL Z540-1-1994
  • ATEX DIRECTIVE 2014/34/EU for electrical and mechanical equipment for use in explosive atmospheres

Applications

Applications

N/A Health and Usage Monitoring Systems (hums) High-frequency Aircraft/airframe Vibration Measurements Rotor, Track and Balance (rtb) Transmission Vibration Measurements

Features

Features

N/A Case Isolated Eliminates need for Separate Mounting Bracket IEPE Integral Cable Integral Mounting Bracket Multiple Sense Directions Available