Housing Material |
N/A Titanium |
Maximum Weight (Less Cable) |
N/A 0.28 oz8 g |
Mounting Provision |
N/A 1/4-28 UNF-2A |
Element Style Material |
N/A Quartz |
Connector Type |
N/A Coaxial 10-32 Plug |
Element Style Type |
N/A Planar Shear |
Integral Cable |
N/A Twisted Pair, PTFE |
Environmental Seal |
N/A Hermetic |
Coefficient of Thermal Sensitivity |
N/A 0.03 %/°F0.05 %/°C |
Peak Maximum Shock (±) |
N/A ±1,177,200 m/s²±120,000 g |
Temperature Range, Sensor |
N/A -10 to +250 ºF-12 to +121 ºC |
Temperature Range, Integral cable |
N/A -76 to +392 ºF-60 to +200 ºC |
Resonant Frequency |
N/A Element: > 120 kHzMechanical Filter: > 10.5 kHz |
Root-Mean-Square (RMS) Broadband Resolution |
N/A 1.0 g9.81 m/s² |
Maximum Transverse Sensitivity |
N/A 5 % |
Strain Sensitivity |
N/A 0.0005 g/µε0.0049 m/s²/µε |
Frequency Range ±3db |
N/A 10 to 10,000 Hz |
Note for Linearity |
N/A Measured using zero-based straight line method, % of F.S. or any lesser range. |
Sensitivity ±20% |
N/A 0.05 mV/G0.005 mV/m/s² |
Note for Sensitivity ±20% |
N/A Measured at 100Hz, 10 g RMS per ISA RP 37.2 |
Peak Measurement Range |
N/A ±60,000 ±588,600 g |
Linearity (±) |
N/A 1 % |
Discharge Time Constant |
N/A 1.0 to 2.0 sec |
Typical Output Impedance |
N/A 100 O |
Direct Current (DC) Compliance Voltage Range |
N/A +18 to +30 V |
Ground Isolation |
N/A >10 MO |
Power Supply Current Range |
N/A 2 to 20 mA |
Warm up Time (to 10 Percent (%) of Bias) |
N/A <8 sec |
Note for Power Supply Current Range |
N/A Do not apply power to this system without current limiting, 20 mA MAX. To do so will destroy the IC amplifier. |
Electrical Filter |
N/A Two Pole |
Electrical Filter Cutoff Frequency |
N/A 7 kHz |
Direct current (DC) Output Bias Voltage |
N/A 7.0 to 12.0 V |