Sensitivity |
N/A 300 mV/g30.6 mV/m/s² |
Sensitivity Tolerance (±) |
N/A 10 % |
Note for Sensitivity |
N/A Measured at 100 Hz, 5 Grms per ISA RP 37.2. |
Minimum Peak Acceleration Range (±) |
N/A 3 g29.4 m/s² |
Frequency Response for X and Y-Axis |
N/A 0 to 1,600 Hz |
Frequency Response for Z-Axis |
N/A 0 to 550 Hz |
Frequency Response Tolerance |
N/A -3 dB |
Resonant Frequency |
N/A > 5.5 kHz |
Full Scale (F.S.) Linearity (±) |
N/A 0.3 % |
Note for Full Scale (F.S.) Linearity (±) |
N/A Linearity is % of specified full scale (or any less full-scale range), zero-based best fit straight line method. |
Maximum Transverse Sensitivity |
N/A 5 % |
Spectral Noise for X and Y-Axis |
N/A 175 µg rms/√ Hz1,717 µm/s² rms/√ Hz |
Spectral Noise for Z-Axis |
N/A 300 µg rms/√ Hz2,943 µm/s² rms/√ Hz |
Sensitivity Change Due to Temperature (±) |
N/A 0.006 %/°F0.01 %/°C |
Housing Material |
N/A Aluminum, Anodized |
Maximum Weight (Less Cable) |
N/A 0.21 oz6.0 g |
Mounting |
N/A 2 x M2 Screws |
Cable Type |
N/A 6-Conductor |
Cable Material |
N/A Santoprene |
Housing Isolation |
N/A Case Isolated |
Maximum Peak Shock |
N/A 10,000 g98,100 m/s² |
Maximum Peak Vibration (±) |
N/A 5,000 g49,050 m/s² |
Operating Temperature Range |
N/A -40 to +185 ºF-40 to +85 ºC |
Environmental Seal |
N/A Epoxy |
Power Supply Current |
N/A 300 µA |
Direct Current (DC) Supply Voltage |
N/A 4 to 28 V |
Typical Output Impedance |
N/A 100 O |
Direct Current (DC) Operating Bias Voltage for X and Y-Axis |
N/A 1.3 to 1.7 V1.35 to 1.65 V |
Direct Current (DC) Operating Bias Voltage for Z-Axis |
N/A 1.2 to 1.8 V |
Direct Current (DC) Output Voltage Range (±) |
N/A 1.0 V |
Self-Test Output for X-Axis |
N/A -150 to -600 mV |
Self-Test Output for Y-Axis |
N/A +150 to +600 mV |
Self-Test Output for Z-Axis |
N/A +150 to +1000 mV |
Turn-On Time |
N/A 1 ms |